Product Introduction of Drug Melting Point Apparatus

10000
Office & School Supplies/Laboratory Supplies/Other Laboratory Supplies


Contact Info
  • Building 1, No. 5500 Yuanjiang Road, Minhang District, Shanghai,
  • 高洁
  • 13761436048
  • 3982822529@qq.com

Drug Melting Point Tester refers to the temperature at which a substance changes from a solid state to a liquid state. Different substances and different purities have different melting points. Therefore, the determination of the melting point is one of the important methods for identifying substances and their purity. Thus, the determination of the melting point plays a very important role in industries such as the chemical industry and pharmaceutical industry. The melting point tester is an instrument for simply determining and researching drugs, spices, dyes, and other crystalline substances.

Drug Melting Point Tester uses a mercury thermometer for measurement and a pointer-type voltmeter to adjust the heating power, which is a traditional and old-fashioned original melting point determination method. This method is reliable and accurate. The instrument electronically heats the melting point capillary, controls the heating rate by adjusting the voltage, and observes the clear melting process through a magnifying glass. The initial melting and final melting temperatures are determined using a traditional mercury thermometer.

Technical Parameters:

1. Temperature measurement range: 50-300℃

2. Heating rate: 1℃/min, 2℃/min, 4℃/min, 6℃/min

3. Measurement accuracy: ±1℃

4. Power: 100W

5. External dimensions: 200×150×215mm

6. Power supply voltage: 220V, 50Hz

7. Thermometer reading, direct heating

8. If higher observation accuracy is required, a dedicated segmented melting point thermometer can be optionally equipped.

A set of four thermometers costs 2200 yuan. Ranges: 0-100℃, 80-180℃, 160-260℃, 240-340℃. 0.5℃ per division

Uses a mercury thermometer for measurement and a pointer-type voltmeter to adjust the heating power, which is a traditional and old-fashioned original melting point determination method. This method is reliable and accurate. The instrument electronically heats the melting point capillary, controls the heating rate by adjusting the voltage, and observes the clear melting process through a magnifying glass. The initial melting and final melting temperatures are determined using a traditional mercury thermometer.

Technical Parameters:

1. Temperature measurement range: 50-300℃

2. Heating rate: 1℃/min, 2℃/min, 4℃/min, 6℃/min

3. Measurement accuracy: ±1℃

4. Power: 100W

5. External dimensions: 200×150×215mm

6. Power supply voltage: 220V, 50Hz

7. Thermometer reading, direct heating

8. If higher observation accuracy is required, a dedicated segmented melting point thermometer can be optionally equipped.

A set of four thermometers costs 2200 yuan. Ranges: 0-100℃, 80-180℃, 160-260℃, 240-340℃. 0.5℃ per division